{"product_id":"mtp®-trunk-cable-pre-terminated-factory-tested-high-density-backbone-solution","title":"MTP® Trunk Cable – Pre-terminated, Factory-Tested High-Density Backbone Solution","description":"\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eEngineered for modern hyperscale data centers and high-bandwidth AI\/Cloud infrastructure, our MTP® trunk cables deliver ultra-low loss, exceptional durability and maximum space efficiency. All connectors are supplied by USConec in partnership with \u003c\/span\u003e\u003cspan\u003e\u003cspan style=\"font-family: Arial;\"\u003eDFT\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e, ensuring industry-leading performance and reliability.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0758\/0362\/3703\/files\/7_711ff087-2415-426a-8773-b8c6818c9bbb.png?v=1786793090\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0758\/0362\/3703\/files\/7_711ff087-2415-426a-8773-b8c6818c9bbb.png?v=1786793090\" alt=\"\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003cdiv align=\"center\"\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"155\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"270\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"155\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eConnector A\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"270\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eUS Conec MTP® Elite, \u003c\/span\u003e\u003cspan\u003e\u003cspan style=\"font-family: Arial;\"\u003eM\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eale \u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"155\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eConnector B\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"270\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eUS Conec MTP® Elite, \u003c\/span\u003e\u003cspan\u003e\u003cspan style=\"font-family: Arial;\"\u003eM\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eale \u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"155\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eFiber Count\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"270\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e72 Fibers (Base-\u003c\/span\u003e\u003cspan\u003e\u003cspan style=\"font-family: Arial;\"\u003e12\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e)\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"155\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eFiber Type\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"270\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eOS2 Single-Mode, 9\/125μm, G.657.A1\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"155\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003ePolish Type\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"270\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eAPC to APC\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"155\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003ePolarity\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"270\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eType B\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"155\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eInsertion Loss\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"270\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Arial;\"\u003e≤ 0.35dB (Typical: 0.15dB) \u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"155\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eReturn Loss\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"270\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Arial;\"\u003e≥ 65dB\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"155\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eAttenuation\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"270\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Arial;\"\u003e≤ 0.35dB\/km @ 1310nm; ≤ 0.21dB\/km @ 1550nm\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"155\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eOperating Wavelength\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"270\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e1310nm \/ 1550nm\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"155\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eMinimum Bend Radius\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"270\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e10mm\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"155\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eCable Jacket\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"270\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eOFNP (Plenum Rated), Double Jacket\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"155\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eBreakout Length\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"270\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e0.84m\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"155\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eCable Outer Diameter\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"270\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e8.5 – 9.0mm\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"155\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eBreakout Outer Diameter\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"270\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e2.0mm\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"155\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eLong-Term Tensile Load\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"270\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e200N\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"155\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eShort-Term Tensile Load\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"270\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e660N\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"155\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"270\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e-10°C to 60°C (14°F to 140°F)\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"155\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eStorage Temperature\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"270\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e-10°C to 70°C (14°F to 158°F)\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cb\u003e\u003cspan\u003eCore Advantages\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\n\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt Times New Roman;\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan class=\"15\"\u003eUltra-Low Loss Performance\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e: MTP® Elite connectors deliver industry-leading insertion loss performance, enabling longer transmission distances and supporting more splice\/connector points without signal degradation \u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt Times New Roman;\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan class=\"15\"\u003ePre-Terminated \u0026amp; Factory Tested\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e: All assemblies are fully terminated and 100% tested in-factory, reducing on-site installation time and labor costs.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt Times New Roman;\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan class=\"15\"\u003eRobust Double Jacket Construction\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e: Plenum-rated OFNP double jacket provides enhanced crush resistance and mechanical stability for long-haul backbone routes.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt Times New Roman;\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan class=\"15\"\u003eBase-\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan class=\"15\"\u003e\u003cspan style=\"font-family: Arial;\"\u003e12\u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan class=\"15\"\u003e High Density Design\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e: 72-fiber base-\u003c\/span\u003e\u003cspan\u003e\u003cspan style=\"font-family: Arial;\"\u003e12\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e configuration is optimized for 400G\/800G parallel optical modules, ideal for AI data center high-density rack deployment \u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt Times New Roman;\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan class=\"15\"\u003eTrusted Branded Components\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e: Genuine US Conec MTP® Elite connectors ensure consistent performance and compliance with TIA\/EIA-604-5 and IEC-61754-7 standards \u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch3\u003e\n\u003cb\u003e\u003cspan\u003e Typical Applications\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\n\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt Times New Roman;\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan\u003eHyperscale Data Center Backbone Cabling\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt Times New Roman;\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan\u003eAI\/Cloud Computing High-Density Rack Deployment\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt Times New Roman;\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan\u003eEnterprise Core \u0026amp; Zone Distribution\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt Times New Roman;\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan\u003eInterconnect Between Main Distribution Area (MDA) and Zone Distribution Area (ZDA)\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt Times New Roman;\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan\u003e400G\/800G High-Bandwidth Parallel Optical Links\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p\"\u003e\u003cspan class=\"16\"\u003eMTP® is a registered trademark of US Conec Ltd. High-performance MTP® products are supplied in partnership between US Conec and \u003c\/span\u003e\u003cspan class=\"16\"\u003e\u003cspan style=\"font-family: Arial;\"\u003eDFT\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"16\"\u003e\u003cspan style=\"font-family: Arial;\"\u003etelecom\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"16\"\u003e.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e","brand":"DFT TELECOM","offers":[{"title":"Default Title","offer_id":54688637387031,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0758\/0362\/3703\/files\/7_711ff087-2415-426a-8773-b8c6818c9bbb.png?v=1786793090","url":"https:\/\/dfttelecom.com\/ar\/products\/mtp%c2%ae-trunk-cable-pre-terminated-factory-tested-high-density-backbone-solution","provider":"DFT TELECOM ","version":"1.0","type":"link"}